Category Gas Zone Dust Zone
CAT 1
0
20
CAT 2
1
21
CAT 3
2
22

 

Description
Group II Non Mining Equipment
GD Gas and Dust
T5 Temperature Class (Gas)
T100°C Maximum Surface Temperature (Dust)
Tamb -10°C to 40°C Ambient Operating Temperature -10°C to 40°C

 

Zones
20 Dust Clouds Likely to be present for long periods
21 Dust Clouds Likely to be present occasionally in normal operation
22 Dust Cloud Unlikely to occur in normal operation, but if it does, will only exist for a short period
0 Flammable Atmosphere highly likely to be present for long periods or continuously
1 Flammable atmosphere possible but unlikely to be present for long periods
2 Flammable atmosphere unlikely to be present exept for short periods of time – typically as a result of a fault condition

防爆指令


迈康标准型IBC粉体下料和填充设备都已核准为第二类设备。 标准如下:


Certification

 

第二类产品 GD c T5 T 100°C,环境温度:-10°C至 40°C

 

在某些情况下,用户可根据使用需要求其设备内部的部分零件达到第一类标准。 这种情况下,该设备的验证及标签如下:


Certification

 

第1/2类产品 c T5 T100°C,环境温度 -10°C 至40°C

 

防爆指令94/9/EC的目标

 

指令94/9/EC的目标是确保产品可以在欧盟地区自由流通。 因此,基于欧共体条约第95条,该指令规定适用标准和生产程序,以确保产品的符合规定。

 

该指令提出应该遵循1985年5月7日会议决议通过的新方案以及涉及安全的基本要求以及其它能够保证生产安全的待定条款。 这些基本的健康和安全要求(EHSRs)均列于指令94/9/EC的附录II中。

 

这些基本的健康和安全条款对以下方面做出了明确规定:

  • 对于在易燃易爆坏境中使用的设备的潜在火源;
  • 自主保护系统需要在爆炸发生后立即运作,主要抑制爆炸源同时(或)削弱 爆炸产生的火焰以及冲击;
  • 安全装置用于保障在火源处设备和自主保护系统的安全运行;

  • 对该设备或自主保护系统的安全功能至关重要却无自主保护功能的部件。

从2003年7月1日起,此类产品必须符合指令94/9/EC(和其它相关法规),并且按照设计意图在特定环境中使用才能够在欧洲市场上自由流通。

 

指令94/9/EC第一次对非电气设备以及在危险环境中使用的可能因粉尘而产生爆炸的设备以及保护系统提出了适用要求。 在非易爆环境中使用的安全装置也包含在内。这些装置对于设备安全运行或防爆系统的功能是必要的或有辅助功能。 此项规定较原国家易爆区使用的设备和系统法规在范围上有所扩展。

 